Senseair K30

ID:K30 series
• Flexible • Easy to configure • Maintenance-free
  • Senseair K30 is a flexible product with two analogue outputs and two digital outputs that can be configured with SADK hardware and UIP or other custom software to meet your requirement.
    The platform can be customised for a variety of sensing and control applications. This platform is designed to be an OEM module for built-in applications in a host apparatus.
    Measured gas                         :  Carbon dioxide (CO2)
    Operating principle                 : Non-dispersive infrared (NDIR)
    Measurement range                : CO2 0–5000ppm
    Accuracy CO2                          : ±30ppm ±3% of reading
    Dimensions                              : 51 x 58 x 12mm 1
    Life Expectancy                        : >15 years
    Operating temperature range :  0–50°C
    Operating humidity range       : 0–95%RH (non-condensing)
    Power supply                           : 4.5–14VDC
    Communication                       :I2C, UART (Modbus)
    OUT1 Linear Output 0–4VDC = 0–2000ppm
    OUT2 Linear Output 1–5VDC = 0–2000ppm
    OUT3 Digital Output On ≥800ppm, Off ≤700ppm
    OUT4 Digital Output On ≥1000ppm, Off ≤900ppm
We use cookies technology to customize content and analysis traffic to our site. We share information about your use of our site with our trusted advertising and analytics partners. Read our accessibly written privacy and cookie policy for full details. If you continue to use our site, we will assume that you are agree to receive cookies for these purposes.   Privacy Policy